- Extract trench channels from original 1F site plan DWG (same origin as hall frames) via streaming DXF tag parser that walks xref BLOCK contents and resolves INSERT-chain transforms (missed by top-level iteration, which caused the earlier 'no trench layer in K2' misjudgment). - Power trunk plan (E3-59~69) used as cross-validation only: its util-line xref is a cropped copy (x<=509.2m) with ~3.5m phase offset; angle clusters (0/+-11/-12 deg) confirm frame rotation alignment. - Generator tools/cad/extract_trench_seed_k2.py: frame rotation, horizontal clip (Liang-Barsky), >=30m runs, 1.5m twin-line merge, 6m point sampling (V61 convention). H6 9 / H7 H8 H9 H10 14 channels each, is_assumed=false. - All halls H1-H10 now have measured trench (PLANNING R4 resolved). - Docs: cad-extraction.md V66 section, OWNER_FEEDBACK log. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com> |
||
|---|---|---|
| .. | ||
| cad-extraction.md | ||
| coex-website.md | ||
| kintex-website.md | ||
| mobile-benchmark-exhibition-performance.md | ||
| nifty-design-refs.md | ||
| reroomai-source.md | ||
| ticketing-app-benchmark.md | ||